Food-Grade Liquid Silicone Rubber IOTA LSR 3230 Series for Baby Care, Food Contact, and Seals: How to Select and Cure?

Hits: 1717 img

Direct Answer

IOTA LSR 3230 Series A/B is a food-grade liquid silicone rubber product. Main features include two-component 1:1 mixing ratio, excellent mold release, fast heat curing, and excellent mechanical properties, and it complies with BfR, FDA, and ROHS. Typical applications include baby care, food contact, seals, and other injection-molded products. Curing data: for 2 mm thickness, 90 seconds at 130°C; 45 seconds at 150°C.

The series includes IOTA LSR 3230, 3240, 3250, and 3260. Cured hardness (125±2°C, 5 min) is 30, 40, 50, and 60, respectively; tensile strength is about 7.5, 8, 10, and 9 MPa; elongation is about 650%, 580%, 500%, and 420%; tear strength is 30 N/mm for 3230, 30 N/mm for 3240, not given for 3250, and 38 N/mm for 3260. The product data also explicitly state that all values are specific and should not be accepted as standard specifications. These data should therefore serve as selection references, and actual acceptance should follow the current batch technical data and project agreement.

Selection should not rely only on “food grade” or “complies with BfR, FDA, ROHS.” First confirm the specific application and contact medium, product structure and thickness, mold and release method, same-batch A/B 1:1 metering and mixing, whether the material is thoroughly stirred, curing temperature and time, hardness grade selection, and the regulatory compliance and migration testing required for the final product. This article does not equate raw-material compliance statements with final-product compliance, nor does it apply the 2 mm curing conditions to all thicknesses. IOTA can provide liquid silicone rubber raw materials and corresponding product data; the company does not provide complete formulations or formulation development services.

1. First Ask What LSR 3230 Series Is Expected to Solve

The series is used for baby care, food contact, seals, and other injection-molded products. Different applications focus on different points: baby care on safety compliance, soft feel, and durability; food contact on regulatory compliance, migration, and odor; seals on compression set, rebound, sealing force, and media resistance; other injection-molded products on flow, release, and molding efficiency. Within the series, hardness ranges from 30 to 60 across 3230 to 3260. Selection should start with product structure, feel, assembly force, and service temperature, not just “food grade” or “pick a hardness.”

2. What to Specify in an Inquiry or Sample Request

What to confirm What to specify in an inquiry or sample request
Application and contact medium Baby care, food contact, seals, or other injection-molded products; contact substance, service temperature, and time
Regulation and compliance Required food-contact regulations (e.g., BfR, FDA), ROHS, and customer restricted-substance list; type and batch of compliance documents required
Product structure and mold Product dimensions, thickest section, mold material, release method, whether release agent is used
Mixing and metering Two-component A:B = 1:1; only same-batch A/B may be mixed; metering accuracy, mixing uniformity, workable time, and injection equipment
Material pretreatment Whether thoroughly stirred before transfer to container; whether fillers or colorants are uniformly dispersed
Curing conditions Curing temperature and time; data give 130°C/90 s and 150°C/45 s for 2 mm thickness; confirm with actual product thickness and equipment
Hardness grade selection 3230/3240/3250/3260; select with product structure, feel, sealing, assembly force, and service temperature, not hardness alone
Acceptance criteria Hardness, tensile strength, tear strength, elongation, compression set, rebound, sealing force, media resistance, odor, migration, etc.
Sample preparation Sample size, thickness, mold condition, vulcanization conditions, secondary heating, whether evaluated after aging or migration, sample quantity

If the customer already has a test specification, obtain the original document first. When criteria are missing, confirm them with the project owner and test laboratory before making samples, so that both sides do not discover different interpretations of “pass” after testing.

3. Check Same-Batch Mixing, Stirring, and Curing Before Discussing Performance

IOTA LSR 3230 Series uses a two-component 1:1 mixing ratio. Important notes: the product is platinum-catalyzed, with the platinum catalyst in Component A; strict care is required during use to avoid catalyst poisoning. Only Component A and Component B of the same batch number may be mixed together. To ensure optimum flow and uniformity, the material must be thoroughly stirred before transfer into a container.

In production, confirm metering accuracy, mixing uniformity, workable time, and injection equipment. The data give 90 seconds at 130°C and 45 seconds at 150°C for 2 mm thickness. These conditions correspond to a specific thickness and cannot be directly applied to thicker or more complex products. The cured property data correspond to vulcanization at 125±2°C for 5 min and should also be checked against the actual vulcanization conditions of the target product.

4. Food-Grade and Compliance Statements Must Be Carried Through to the Final Product

The product data state compliance with BfR, FDA, and ROHS. This is raw-material-level compliance information and does not mean the final product is automatically compliant. For food contact and baby care, obtain the corresponding regulatory compliance statements and, where necessary, migration test reports, and evaluate against the customer restricted-substance list. The final product must also be evaluated with formulation, process, additives, vulcanization conditions, and contact conditions.

For seals, grip and sealing performance cannot be judged only by hardness or tensile strength; compression set, rebound, dimensional stability, media resistance, and actual assembled sealing force should also be evaluated. The 3230 to 3260 grades have different hardness and should be selected according to the seal structure, assembly force, and media conditions, not hardness alone.

5. Typical Properties Are Conditional Data; the Data Explicitly State They Are Not Standard Specifications

Technical data: Component A is transparent with density about 1.11–1.12 g/cm³ and viscosity about 250–320 (23°C, 10 s⁻¹); Component B is transparent with viscosity about 230–280. After curing (125±2°C, 5 min): transparent, density about 1.11–1.12 g/cm³, 3230/3240/3250/3260 hardness 30/40/50/60, tensile strength 7.5/8/10/9 MPa, elongation 650%/580%/500%/420%, and tear strength 30/30/—/38 N/mm (not given for 3250).

The product data explicitly state that all values are specific and should not be accepted as standard specifications. These data should therefore serve as selection references and a basis for batch comparison. Acceptance criteria should be separately agreed between the project owner and supplier; typical values should not be written directly as pass limits in procurement specifications. Mold release and mechanical properties should also be evaluated with the specific mold and process; release performance depends on mold material, surface condition, product structure, and cure degree.

6. Prepare Samples in This Order Before Sending

  1. Obtain the customer’s service conditions, regulatory requirements, and acceptance criteria; confirm whether food contact, baby care, ROHS, mechanical properties, and sealing requirements are targets or existing results.

  2. Specify application, contact medium, product structure and thickest section, mold, same-batch A:B = 1:1 mixing/metering, material stirring, curing temperature and time, hardness grade, and post-treatment arrangement.

  3. Check the current IOTA LSR 3230 Series data and batch compliance documents, then have the user make representative samples and keep records of mixing, injection, vulcanization, release, and post-treatment.

  4. Arrange tests as agreed; keep sample identity, test conditions, observation photos, and evaluation results in the report. Before expanding use, confirm whether the samples represent actual workpieces.

IOTA/Anhui Iota Silicone Oil Co., Ltd. positions itself as a solution provider across the organosilicon industry chain and can provide liquid silicone rubber raw materials and corresponding product data. When communicating, provide the final product, contact medium, regulatory requirements, sealing conditions, mold, and curing equipment together to facilitate candidate screening; the company does not provide complete formulations or formulation development services.

FAQ

1. Does compliance with BfR, FDA, and ROHS mean the final product is definitely compliant?

No. These are raw-material-level compliance statements. The final product must also be evaluated with formulation, process, additives, vulcanization conditions, and contact conditions, and corresponding compliance documents and necessary migration test reports must be obtained.

2. Can 130°C/90 s or 150°C/45 s for 2 mm be directly used for thicker products?

No. Curing time varies with thickness, mold temperature, injection amount, and equipment efficiency. Confirm with the thickest section and representative samples.

3. Why may only same-batch A/B be mixed?

The data explicitly require that only Component A and Component B of the same batch number be mixed together. Mixing different batches may affect metering, curing, and property consistency; follow the customer’s raw-material management and supplier requirements.

4. How can platinum catalyst poisoning be avoided?

The platinum catalyst is in Component A. Strict care is required during use to avoid contact with substances known to poison platinum catalysts. Specific material compatibility should be included in the customer’s raw-material approval and site management requirements.

5. How to choose between 3230 and 3260?

Select with product structure, feel, assembly force, sealing requirements, and service temperature, not hardness alone. Different hardness grades also differ in tensile strength, elongation, and tear strength and should be evaluated with the target product.

6. Can the technical data be used directly as acceptance criteria?

Not directly. The data explicitly state that all values are specific and should not be accepted as standard specifications. Acceptance criteria should be separately agreed between the project owner and supplier, with typical data serving as selection references and a basis for batch comparison.

7. Why is the tear strength for 3250 shown as “—”?

The data do not give a tear strength value for 3250. For sample requests and acceptance, obtain the current batch data for that grade from the supplier; do not fill in or apply values from other grades.