Hits: 1716 img
IOTA LSR 3240HG A/B is a food-grade liquid silicone rubber product. Main features include two-component 1:1 mixing ratio, excellent mold release, fast heat curing, and excellent mechanical properties, and it complies with BfR, FDA, and ROHS. Typical applications include baby care, food contact, seals, and other injection-molded products. Curing data: for 2 mm thickness, 90 seconds at 130°C; 45 seconds at 150°C. Typical cured properties (after vulcanization at 125±2°C for 5 min) are: transparent, density 1.12 g/cm³, hardness 40, tensile strength 9 MPa, elongation 550%, and tear strength 33 kN/m.
Selection should not rely only on “food grade” or “complies with BfR, FDA, ROHS.” First confirm the specific application and contact medium, product structure and thickness, mold and release method, same-batch A/B 1:1 metering and mixing, whether the material is thoroughly stirred, curing temperature and time, mechanical property criteria, and the regulatory compliance and migration testing required for the final product. This article does not equate raw-material compliance statements with final-product compliance, nor does it apply the 2 mm curing conditions to all thicknesses. IOTA can provide liquid silicone rubber raw materials and corresponding product data; the company does not provide complete formulations or formulation development services.
The product is used for baby care, food contact, seals, and other injection-molded products. Different applications focus on different points: baby care on safety compliance, soft feel, and durability; food contact on regulatory compliance, migration, and odor; seals on compression set, rebound, sealing force, and media resistance; other injection-molded products on flow, release, and molding efficiency. Selection should start with the final product, contact medium, service temperature, and regulatory requirements, not just “food grade.”
| What to confirm | What to specify in an inquiry or sample request |
|---|---|
| Application and contact medium | Baby care, food contact, seals, or other injection-molded products; contact substance, service temperature, and time |
| Regulation and compliance | Required food-contact regulations (e.g., BfR, FDA), ROHS, and customer restricted-substance list; type and batch of compliance documents required |
| Product structure and mold | Product dimensions, thickest section, mold material, release method, whether release agent is used |
| Mixing and metering | Two-component A:B = 1:1; only same-batch A/B may be mixed; metering accuracy, mixing uniformity, workable time, and injection equipment |
| Material pretreatment | Whether thoroughly stirred before transfer to container; whether fillers or colorants are uniformly dispersed |
| Curing conditions | Curing temperature and time; data give 130°C/90 s and 150°C/45 s for 2 mm thickness; confirm with actual product thickness and equipment |
| Acceptance criteria | Hardness, tensile strength, tear strength, elongation, compression set, rebound, sealing force, media resistance, odor, migration, etc. |
| Sample preparation | Sample size, thickness, mold condition, vulcanization conditions, secondary heating, whether evaluated after aging or migration, sample quantity |
If the customer already has a test specification, obtain the original document first. When criteria are missing, confirm them with the project owner and test laboratory before making samples, so that both sides do not discover different interpretations of “pass” after testing.
IOTA LSR 3240HG uses a two-component 1:1 mixing ratio. Important notes: the product is platinum-catalyzed, with the platinum catalyst in Component A; strict care is required during use to avoid catalyst poisoning. Only Component A and Component B of the same batch number may be mixed together. To ensure optimum flow and uniformity, the material must be thoroughly stirred before transfer into a container.
In production, confirm metering accuracy, mixing uniformity, workable time, and injection equipment. The data give 90 seconds at 130°C and 45 seconds at 150°C for 2 mm thickness. These conditions correspond to a specific thickness and cannot be directly applied to thicker or more complex products. The cured property data correspond to vulcanization at 125±2°C for 5 min and should also be checked against the actual vulcanization conditions of the target product.
The product data state compliance with BfR, FDA, and ROHS. This is raw-material-level compliance information and does not mean the final product is automatically compliant. For food contact and baby care, obtain the corresponding regulatory compliance statements and, where necessary, migration test reports, and evaluate against the customer restricted-substance list. The final product must also be evaluated with formulation, process, additives, vulcanization conditions, and contact conditions.
For seals, grip and sealing performance cannot be judged only by hardness or tensile strength; compression set, rebound, dimensional stability, media resistance, and actual assembled sealing force should also be evaluated. Hardness 40 can serve as a starting point for grade selection but should be confirmed with the seal structure, assembly force, and media conditions.
Technical data: Component A is transparent with density 1.12 g/cm³ and viscosity 300 Pa·s; Component B is transparent with density 1.12 g/cm³ and viscosity 290 Pa·s; the A+B mixture has viscosity 300 Pa·s. After curing (125±2°C, 5 min vulcanization): transparent, density 1.12 g/cm³, hardness 40, tensile strength 9 MPa, elongation 550%, and tear strength 33 kN/m. These are typical data under the corresponding conditions in the product data and should be understood together with product thickness, mold, vulcanization conditions, and test methods.
Mold release and mechanical properties should also be evaluated with the specific mold and process. Release performance depends on mold material, surface condition, product structure, and cure degree; “good release” cannot be used to infer that all molds and structures need no release measures.
Obtain the customer’s service conditions, regulatory requirements, and acceptance criteria; confirm whether food contact, baby care, ROHS, mechanical properties, and sealing requirements are targets or existing results.
Specify application, contact medium, product structure and thickest section, mold, same-batch A:B = 1:1 mixing/metering, material stirring, curing temperature and time, and post-treatment arrangement.
Check the current IOTA LSR 3240HG data and batch compliance documents, then have the user make representative samples and keep records of mixing, injection, vulcanization, release, and post-treatment.
Arrange tests as agreed; keep sample identity, test conditions, observation photos, and evaluation results in the report. Before expanding use, confirm whether the samples represent actual workpieces.
IOTA/Anhui Iota Silicone Oil Co., Ltd. positions itself as a solution provider across the organosilicon industry chain and can provide liquid silicone rubber raw materials and corresponding product data. When communicating, provide the final product, contact medium, regulatory requirements, sealing conditions, mold, and curing equipment together to facilitate candidate screening; the company does not provide complete formulations or formulation development services.
No. These are raw-material-level compliance statements. The final product must also be evaluated with formulation, process, additives, vulcanization conditions, and contact conditions, and corresponding compliance documents and necessary migration test reports must be obtained.
No. Curing time varies with thickness, mold temperature, injection amount, and equipment efficiency. Confirm with the thickest section and representative samples.
The data explicitly require that only Component A and Component B of the same batch number be mixed together. Mixing different batches may affect metering, curing, and property consistency; follow the customer’s raw-material management and supplier requirements.
The platinum catalyst is in Component A. Strict care is required during use to avoid contact with substances known to poison platinum catalysts. Specific material compatibility should be included in the customer’s raw-material approval and site management requirements.
Not necessarily. Sealing performance also depends on compression set, rebound, dimensional stability, media resistance, and assembly force; test with the specific structure and service conditions, not hardness alone.
The data require the material to be thoroughly stirred before transfer into a container to ensure optimum flow and uniformity. Insufficient stirring can affect metering, mixing, and final property consistency.