Optical Liquid Silicone Rubber IOTA LSR 3G30 Series for Optical Lenses, Automotive Lighting, and High-Definition Displays: How to Select and Validate?

Hits: 1725 img

Direct Answer

IOTA LSR 3G30 Series is an optical liquid silicone rubber. Applications include optical lenses (secondary optical lenses, nose pads, light-guide devices, etc.), optical devices and transparent products (such as bottles, Bluetooth earphones, cups, earplugs, light-guide columns, etc.), automotive lighting, and high-definition displays. Product features include excellent transparency, high light transmittance, excellent UV resistance and heat resistance, good processing and molding performance suitable for injection and potting processes, and platinum catalysis suitable for the food industry.

Technical data give six hardness grades from 3G30 to 3G80, with hardness of 30, 40, 50, 60, 70, and 80; viscosity about 50,000/50,000/40,000/40,000/35,000/40,000 mPa·s (25°C); tensile strength about 1.8–8.0 MPa; elongation about 150%/160%/180%/180%/150%/50%; tear strength about 6–12 kN/m; transmittance 92% for all (450 nm, 2 mm); density about 1.00–1.05 g/cm³; and refractive index 1.41 for all.

Selection should not rely only on “92% transmittance” or “suitable for the food industry.” First confirm the specific application and optical function, molding method (injection or potting), product thickness and thickest section, A/B metering and mixing, curing conditions, hardness grade selection, and the project acceptance criteria for transmittance, refractive index, UV resistance, heat resistance, dimensional stability, and food-contact compliance. This article does not equate 92% transmittance with optical reliability or long-term UV performance, nor does it equate “platinum catalysis suitable for the food industry” with final-product food-contact compliance. IOTA can provide liquid silicone rubber raw materials and corresponding product data; the company does not provide complete formulations or formulation development services.

1. First Ask What LSR 3G30 Series Is Expected to Solve

The series spans a wide range of applications: optical lenses on transmittance, refractive index, and dimensional stability; light-guide devices and light-guide columns on transparency and light efficiency retention; automotive lighting on heat resistance, UV resistance, and long-term optical stability; high-definition displays on transparency and molding precision; bottles, cups, earplugs, and other transparent products on transparency, feel, and food-contact compliance. Selection should start with the specific optical function, molding method, and target performance, not just “optical silicone.”

2. What to Specify in an Inquiry or Sample Request

What to confirm What to specify in an inquiry or sample request
Application and optical function Secondary optical lens, nose pad, light-guide device, light-guide column, automotive lighting, high-definition display, or other transparent product; main optical metrics
Molding method and mold Injection or potting; mold material, surface finish, release method, whether release agent is used
Product structure and thickness Dimensions, thinnest/thickest sections, optically effective thickness; whether transmittance test thickness matches the product
Mixing and metering A/B ratio and metering accuracy, mixing uniformity, workable time, and equipment; the data do not give the mixing ratio, so confirm with the supplier
Curing conditions Curing temperature, time, and pressure; the data do not give specific conditions, so obtain from the supplier and confirm with product thickness
Hardness grade selection 3G30/3G40/3G50/3G60/3G70/3G80; select with softness, strength, rebound, and assembly requirements
Acceptance criteria Transmittance (including wavelength and thickness), refractive index, UV resistance, heat resistance, dimensional stability, yellowing resistance, food-contact compliance, etc.
Sample preparation Sample size, thickness, mold condition, curing conditions, whether evaluated after aging or light exposure, sample quantity

If the customer already has a test specification, obtain the original document first. When criteria are missing, confirm them with the project owner and test laboratory before making samples, so that both sides do not discover different interpretations of “pass” after testing.

3. Transmittance Must Always Be Stated with Its Test Conditions

The data give 92% transmittance at 450 nm and 2 mm. This value cannot be used without its conditions: transmittance may differ at different wavelengths, thicknesses, surface finishes, and curing conditions. If the optically effective thickness of the product is not 2 mm, 92% cannot be directly treated as the product transmittance; retest at the target thickness and wavelength.

“Excellent transparency and high transmittance” are product feature descriptions and are not the same as optical reliability or long-term UV performance. Automotive lighting and high-definition display applications should also evaluate yellowing resistance, transmittance retention after light exposure, and dimensional stability.

4. Select Refractive Index and Hardness Grade According to Optical and Structural Needs

All six grades have a refractive index of 1.41, meaning the refractive index is consistent across the series; selection differences are mainly in hardness, viscosity, tensile strength, elongation, and tear strength. Hardness ranges from 30 to 80, and elongation drops to 50% at 3G80. Selection should be confirmed with optical structure, assembly force, sealing requirements, and rebound, not hardness alone.

3G30 and 3G40 have viscosity about 50,000 mPa·s, 3G50 and 3G60 about 40,000, 3G70 about 35,000, and 3G80 about 40,000. Injection and potting processes have different viscosity requirements and should be confirmed with equipment, mold structure, and venting design.

5. Understand UV Resistance, Heat Resistance, and Food-Industry Suitability Under Specific Criteria

The product features state excellent UV resistance and heat resistance, but this data set does not give specific UV aging conditions, heat-resistance temperatures, or retention data. Procurement and sample-request documents should list these as criteria to be confirmed and include them in acceptance documents only after the corresponding reports are obtained.

“Platinum catalysis suitable for the food industry” is a product positioning description and is not the same as final-product food-contact compliance. For bottles, cups, earplugs, and other products that may contact food or the human body, obtain the corresponding food-contact regulatory compliance statements and necessary migration test reports, and evaluate against the customer restricted-substance list. The final product must also be evaluated with formulation, process, additives, curing conditions, and contact conditions.

6. Prepare Samples in This Order Before Sending

  1. Obtain the customer’s service conditions and acceptance criteria; confirm whether transmittance (including wavelength and thickness), refractive index, UV resistance, heat resistance, dimensional stability, and food-contact requirements are targets or existing results.

  2. Specify application and optical function, molding method, product structure and thickness, A/B metering and mixing, curing conditions, and hardness grade; request the mixing ratio and curing conditions from the supplier if not given.

  3. Check the current IOTA LSR 3G30 Series data, then have the user make representative samples and keep records of mixing, molding, curing, release, and post-treatment.

  4. Arrange tests as agreed; keep sample identity, test conditions, observation photos, and evaluation results in the report. Before expanding use, confirm whether the samples represent actual optical products.

IOTA/Anhui Iota Silicone Oil Co., Ltd. positions itself as a solution provider across the organosilicon industry chain and can provide liquid silicone rubber raw materials and corresponding product data. When communicating, provide the application, optical structure, molding method, curing equipment, and target defects together to facilitate candidate screening; the company does not provide complete formulations or formulation development services.

FAQ

1. Does 92% transmittance directly represent product transmittance?

It cannot be used without its conditions. The value corresponds to 450 nm and 2 mm; if product thickness, wavelength, surface finish, or curing conditions differ, retest.

2. All six grades have a refractive index of 1.41—how to choose?

When refractive index is consistent, select mainly by hardness, viscosity, tensile strength, elongation, and tear strength. Confirm with optical structure, assembly force, sealing, and rebound requirements, not hardness alone.

3. 3G80 has only 50% elongation—what is it suitable for?

3G80 has hardness 80 and elongation 50%, a high-hardness, low-elongation grade suited to structures requiring higher rigidity and dimensional stability; suitability should be evaluated with the specific optical product, not selected by hardness alone.

4. The data give no A/B mixing ratio or curing conditions—how should samples be submitted?

Request the current batch mixing ratio, metering requirements, and curing recommendation from the supplier, and confirm with product thickness, mold temperature, and potting or injection equipment; do not apply conditions from other series.

5. Are there specific data for UV resistance and heat resistance?

This data set does not give specific UV aging conditions, heat-resistance temperatures, or retention data. Test separately under the target application conditions; “excellent” descriptions cannot replace test results.

6. Does “platinum catalysis suitable for the food industry” mean the final product is compliant?

No. Food-contact compliance also requires corresponding regulatory compliance statements, migration testing, and customer restricted-substance evaluation. The final product must also be evaluated with formulation, process, additives, curing conditions, and contact conditions.

7. What should be noted for automotive lighting?

Focus on heat resistance, UV resistance, yellowing resistance, transmittance retention after light exposure, and dimensional stability, and verify with representative optical samples; initial transmittance alone is not sufficient.

Online QQ Service, Click here

QQ Service

What's App